Section: FieldNorms
This section controls field norms post-processing. Field norms
output the global norm of every plot variable to a text file, writing
a new line for each output time.
The prefix is the label set in incflo.post_processing. For example
incflo.post_processing = fieldnorms. Inputs listed here only address
options specific to field norms; the inputs controlling the output timing
(which are shared by other post-processing types) are listed in the
[post-processing section].
- fieldnorms.type
type: String, mandatory
To use field norms output specify with keyword
FieldNorms
- fieldnorms.mask_redundant_grids
type: Boolean, optional, default = true
Setting this option to true ensures that the field norm calculation does not include cells that are covered by finer cells from a different mesh level. This also ensures that no volume is double counted. Setting it to false makes sure that every cell, covered or not, is included.
- fieldnorms.use_vector_magnitude
type: Boolean, optional, default = false
By default, each component of vector output fields is considered separately. Setting this option to true ensures that the field norm calculation considers the local vector magnitude instead of separating each vector component.
- fieldnorms.norm_type
type: String, optional, default =
2By default, this post-processing routine calculates the volume-weighted L2 norm, corresponding to norm type 2. Other options include the L1 norm, designated by
1, and the L-infinity norm, designated byinfinity.